Part No.0572 1842

  • Operating time 150 days
  • All in one temperature data logger: PDF measurement data, configuration file, acceptance test certificate 3.1 according to DIN ISO 10204 and instruction manual
  • Immediate creation of a PDF report directly after connection to a computer
  • Monitoring transport in compliance with GxP, 21 CFR Part 11, HACCP and EN 12830

With the temperature data logger Testo 184 T2, you can now monitor the transport of sensitive products such as pharmaceuticals, foods or electronics safely and conveniently. Thanks to a start and stop button, the temperature data logger guarantees easiest data recording operation. At their destination, a glance at the display or the LEDs tells you whether the configured limit values have been adhered to during transport.

Product Description
With the temperature data logger testo 184 T2, you monitor the transport of sensitive goods such as pharmaceuticals, foods or electronics. The temperature data logger testo 184 T2 is a disposable data logger which can be used over a maximum period of 150 days.

At their destination, a glance at the display or the LEDs tells you whether the configured limit values have been adhered to. In order to obtain detailed information, it is sufficient to connect the temperature data logger to a PC – a PDF report is immediately generated with all relevant data. In order for you to be able to work even more efficiently and conveniently with the temperature data logger, all required files and information are stored directly and securely in the disposable data logger testo 184 T2: Configuration file, acceptance test certificate 3.1 according to DIN ISO 10204, instruction manual and PDF report of your recorded data.

The measurement value store of the temperature data logger Testo 184 T2 has a capacity of 40 000 measurement values. The measurement rate is freely selectable from 1 min to 24 h.
Testo 184 T2 is compliant with GxP, 21 CFR Part 11, HACCP and EN 12830. Testo AG is an ISO 9001:2008-certified company, and ensures the adherence to the norms through internal audits as well as accredited external audits.
Find out which benefits the temperature data logger Testo 184 T4 provides

Clear alarm indication 
A glance at the the LEDs is enough to know whether limit values have been violated during transport.

Easiest operation 
The disposable data logger testo 184 T2 is intuitively operated, and can be used without special training or previous knowledge concerning transport monitoring: The "Start" button begins data recording. "Stop" ends it.

Easiest configuration
In each Testo 184 T2, a configuration file is stored, with which the configuration of the Testo 184 T2 is childsplay – no download, no installation, no user interface and no additional costs.

Convenient readout 
A PDF report with the transport data is created immediately on connection of the temperature data logger Testo 184 T2 to the USB interface of a computer. This is suitable for long-term archiving according to PDF/A standard.

Mobile readout/printout on site 
All temperature data loggers Testo 184 T2 can be read out on site with an NFC-capable Android smartphone. Data transfer from the data logger to a compatible Testo fast printer (option) also functions wirelessly via NFC.

IT-safe 
The temperature data loggers Testo 184 T2 work securely without software installation or download, so that IT problems are triggered neither by the firewall nor the virus scanner.

Delivery Scope
Temperature data logger Testo 184 T2 for transport monitoring, including acceptance test certificate 3.1 according to DIN ISO 10204 (stored in Testo 184 

      Temperature - NTC
      Measuring range
      -35 to +70 °C
      Accuracy ±0.5 °C
      Resolution 0.1 °C

      General technical data
      Dimensions
      44 x 12 x 97 mm
      Operating temperature -35 to +70 °C
      Protection class IP67 with TopSafe
      Standards EN 12830
      Certificate type Certified by HACCP International
      Operating time 150 days
      Alarm signal by LED and Display
      Battery type Lithium battery non exchangeable
      Memory 40,000 measuring values
      Storage temperature -55 to +70 °C
      Weight 45 g

      Monitoring and documentation of temperature, humidity and shock in food logistics
      Handling foods involves danger to human health at all levels. In order to be able to eliminate them as far as possible, food companies must comply with an HACCP concept which guarantees food safety along the entire production chain – "from farm to fork". The adherence to product-specific limit values and the uninterrupted monitoring of the cold chain are crucial. In many cases, the monitoring of humidity and shock, in addition to temperature, are relevant for the maintenance of food quality.

      With the Testo 184, quality managers in food logistics have six HACCP International-certified data loggers available to them, which monitor and document all critical parameters during the transport of foods. The data loggers Testo 184 T1,T2, T3 and T4 have been additionally tested and certified according to EN 12830 by the TÜV Süd, and are therefore ideally suitable for the transport of refrigerated and deep-frozen foods.

      Monitoring and documentation of temperature and humidity during the transport of flowers
      Researchers discovered long ago that the temperature during the transport of cut flowers and green plants has a crucial influence on their quality. Since flowers are traded globally, and as it is not uncommon for flowers from Kenya, Tanzania or Ecuador to be sold in the USA, Germany or Russia, the monitoring of transport conditions during their often days-long journeys is essential.

      Flowers must be transported neither too warm not too cold. The former results in the loss of blossoms and leaves, the latter involves cold damage, which negatively influences not only the appearance but also the longevity of the plants. Sufficient air humidity is furthermore also of significance for the quality of the flowers.
      With the data loggers Testo 184, measuring instruments are now available to you with which you can monitor and document temperature and humidity in the logistics of cut flowers and green plants quickly, easily and reliably.

      Monitoring and documentation of temperature, humidity and shock in logistic services of all kinds
      Providers of logistic service often take on the responsibility for expensive and sensitive products from the fields of pharmaceuticals, food, electronics or art. The wrong conditions during transport can lead to considerable losses of quality, right up to the complete devaluation of the monitored products.

      With the help of the Testo 184 data logger, the prescribed temperature and humidity limit values as well as the shock tolerance levels can be monitored during transport, and thanks to the automatic report creation, very easily analyzed and documented. This allows all doubts regarding the correct transport conditions to be eliminated.
      Shock-sensitive products such as electronics, delicate machinery or certain bio-pharmaceuticals can be additionally monitored for the violation of previously defined shock limits with the help of the Testo 184 G1.

      Monitoring and documentation of temperature, humidity and shock in pharmaceutical logistics
      Most pharmaceuticals must be continuously transported and stored at defined upper and lower temperature and humidity limit values, along the entire supply chain. A violation of these predefined upper and lower limit values can lead to irreversible alterations of the active ingredients or the composition of the medicaments.

      However, not only medications and their active ingredients are endangered. Minus temperatures or extreme temperature fluctuations can also cause damage to containers or medical instruments. The consequence is the threat of spoilage of the entire goods, financial losses and damage to reputation.

      In GxP-compliant quality management, the control of the entire cold chain, from production to delivery, is therefore a prerequisite, in order not only to ensure product quality, but also to prevent financial losses and damage to your reputation in the pharmaceutical industry.

      With the Testo 184 data loggers, your products can be protected from unnoticed gaps in the cold chain, and the entire distribution path monitored and documented simply, securely and compliantly with all common standards, guidelines and regulations

        Product Brochures

        Manuals
        Software
        • Testo 184 T2 Configuration (PDF) (This pdf document is a configuration file, therefore you might not be able to open it in your web browser. Please download the data and open it using your Adobe Acrobat Reader.)
        • Domestic Shipping Rates:

          • NZ Standard Shipping $14.00
          • Heavy Good Shipping $24.00
          • Chatham and Stewart Islands $59.00
          • FREE shipping when you spend over $300

          Important note: Please provide a physical address for delivery. We do not deliver to PO Boxes or Parcel Pods.

           

        • Testo Instruments New Zealand
          C/- Eurotec Ltd
          750C Great South Road
          Penrose
          Auckland 1061

          Ph: 09 579 1990
          Email: sales@eurotec.co.nz

        Customer Reviews

        Be the first to write a review
        0%
        (0)
        0%
        (0)
        0%
        (0)
        0%
        (0)
        0%
        (0)